Model No.: ZDB/HDB

Electric Axial Propeller Irrigation Dirty Water Submersible Pump High Efficiency
 
 
<p style="te

Electric Axial Propeller Irrigation Dirty Water Submersible Pump High Efficiency

 

 

Application:

1 The two models ZDB and HDB submersible electric pump can be used in irrigation and drainage of agricultural field
2 The two models ZDB and HDB can also be used in supply and sewerage water of factory, mine, dock, urban construction,
3 The Axial flow submersible electric pump applies to the condition of low lift head, high flow-rate; while the mixed-flow submersible electric pump is very efficient with high performance of cavitation erosion

 

Features:

1 Adopting this type of submersible electric pump is the most through approach for building pump station along the river and lake area where the water level fluctuate greatly, as well as fluctuate the problem of flood prevention of pump; moreover, the major shaft and intermediate shaft are not required any more,and the machine set can operate more steady and reliable.
2 Submersible electric pump has double and triple mechanical seal and F grand insulation (155oC thermostable ) with protection grand IP68 (IEC). The pump has hydraulic model of nationwide unified design, which has high reliability and has the same performance of the conventional hydraulic pump so that the customer can select the model easily.
3 Due to the electric motor is combined with the hydraulic pump, the assembly procedure is no longer necessary for lining up axis of electric motor, transmission mechanism and hydraulic pump on site

 

Model number description:

500: Nominal water outlet caliber of pump (mm)

Z: Axial flow

DB: Electric pump

70: 1/10 of pump specific speed

J: New design, speed down

 

Operation:

You should write down voltage, current and operation time on every two hours and pay attention to observe the stability of operation of the pump.

 

Stop pump:

You can press stop button either on situ control line box or on switch cabinet to stop the operation of pump, but you should carefully select position of switch.

 

Construction:

 

Performance parameter:

350ZDB-80

Installation
angle
Capacity Head
(m)
Speed Power
kW
Eff.
%
D(mm)
Impeller
diameter
m³/h l/s r/min shaft power Motor power
-4° 828 230 6.98 1450 20.8 30 75.79 300
968 269 5.01 16.40 80.40
1094 304 2.64 11.2 70.30
-2° 900 250 7.15 23.30 75.30
1048 291 5.22 18.50 80.40
1177 327 2.89 13 71.49
965 268 7.30 25.90 37 74.05
1116 310 5.41 20.50 80.40
1246 346 3.10 14.3 73.43
+2° 1012 281 7.41 27.20 75.06
1184 329 5.61 22.50 80.40
1332 370 3.39 16.5 74.43
+4° 1073 298 7.59 29.2 75.89
1274 354 5.84 25.20 80.40
1411 392 3.67 18.9 74.76

 

350ZDB-80J

bigPhoto
 Mr. Ms. Emma Huang

Tel: 86-21-50550317
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

GSD Industrial Co., Ltd. [China (Mainland)]


Business Type:Manufacturer
City: Shanghai
Province/State: Shanghai
Country/Region: China (Mainland)

You May Like:

Product (145)